Fire Alarm Annunciator Model 5235 User Manual

SK-5235 Remote Annunciator The SK-5235 remote annunciator provides remote annunciation for the SK-5208 Fire Alarm Control Panel. The SK-5235 performs all system operations. It also provides trouble and alarm information and can be used for programming. The SK-5208 can support up to.

  1. Fire Alarm Annunciator Panel Troubleshooting
  2. Fire Alarm Annunciator Panel Location
  3. Fire Alarm Annunciator Model 5235 User Manual Free
  4. Fire Alarm Annunciator Model 5235 User Manual Pdf
  5. Fire Alarm Annunciator Beeping
  1. 4100ES, and 4100U series fire alarm control panels Also compatible with Simplex legacy panel model series 4002, 4020, 4100, 4120, and Universal Transponders (UT) Supervised RUI (remote unit interface) communications require a single, twisted, shielded wire pair to the fire alarm control panel (power is supplied via a second wire pair).
  2. View and Download ADT -LCD40 user manual online. ADT-LCD40 Series Remote Fire Annunciators. ADT-LCD40 Control Panel pdf manual download. While a fire alarm system.
  3. The Model 5230 Remote Alphanumeric Annunciator can be used to program models 5104, 5204, 5207 and C6000 controls. Programming options include telephone numbers, reporting format, account number, loop response times (electronic retard), test time, output activation, and user and installer codes.
Advertising

16

Fire Alarm Annunciator Panel Troubleshooting

PFC-4410RC • 5403550 • REV Q • 11/12

Lamp Test

When the panel is in a Normal Condition, pushing the two top buttons will illuminate all of the LED's and display for

approximately one second.

Remote Annunciator Model RA-4410RC Operation

Red LED’s:

Initiating Device Circuits Active (4)

Notification/Release Circuits Active (4)

Common Alarm (1)

Green LED’s: AC Power

Yellow LED’s: Initiating Device Circuits troubles (4)

Output Circuit Troubles (4)

Supervisory Initiating Zone (4)

Supervisory Bell Output Active (4)

(1) each: Sup 1/Abort, Supervisory 2, Power Trouble,

Supervisory Trouble, System Trouble, Ground Fault,

Pre-Discharge/Discharging, Alarm Silenced

The appropriate LED flashes to indicate a change of status on the panel. A trouble or supervisory condition will flash the appropriate

Yellow LED indicating the location of the condition. If any outputs are programmed as TROUBLE or SUPERVISORY BELL, that

Yellow output LED will flash indicating the output is activated. Pressing the BUZZER SILENCE button on the panel changes the

flashing zone Amber LED to steady on and turns the flashing Yellow output LED off.

An alarm condition will flash a Red LED indicating the zone in alarm and any outputs mapped to that zone that have activated.

Pressing the SIGNAL SILENCE button changes the flashing Red Zone LED to steady on and the flashing Red Output LED mapped

to that zone off unless the output is programmed as RELEASE. In addition, the Yellow ALARM/ SILENCE LED will light.

Any zone programmed as WATERFLOW is considered non-silenceable so the signal and buzzer silence buttons will have no

effect on the flashing zone and output LED's. A buzzer on the annunciator sounds for any trouble condition. When the panel

has a trouble or supervisory condition, pressing the SILENCE/LAMP TEST button silences the condition at the panel and all

annunciators. When no non-silenced trouble or supervisory conditions exist, pressing the SILENCE/LAMP TEST button can be

used to test the LED's.

Model

The release panel supervises and communicates with the annunciator via separate connections for the RS-485 communication and

24VDC power requirements of the RA-4410RC. Separate cables should be used for power and communication. Shielded cable

shall be used for the communication line. Up to four annunciators can be connected to one panel. A rotary switch is provided on

the panel to indicate how many annunciators are connected. Another rotary switch is on the annunciator to set the address. The

annunciators must be addressed consecutively. See page 89 for wiring information. Refer to bulletin #8840024 for installation

Fire Alarm Annunciator Panel Location

instructions and maximum wire run.

Test Procedure

The system should be inspected, tested and maintained in accordance with NFPA-72 National Fire Alarm Code, Chapter 10 and

any other requirements of the local authority having jurisdiction.

Fruit machine free download - Fruit Machine, The Fruit Machine, Fruit Machine, and many more programs. Fruit machine manual download for windows 10. Welcome to the fruit machine download page. Our latest fruit machine releases for Android / Apple / PC. May 13, 2016  I have a pie factory fruit machine vivid on mpu5 it's stuck on free play but I want it on cash play the door switches have been unplugged and I don't know what wires to use has anyone got any idea what goes where? Thanks my email is lewis.clark2015@outlook.com if someone could also email the mpu5 manual that would be great. May 16, 2017  The classical best fruit theme will definitely please and excite anyone who loves slot machines of a retro style. Start playing a Fruit Machine and get lucky since it is a fantastically simple and cost-effective gamble! Specify a value of your bet and spin the reels.

Test Procedure (Canada)

The system should be inspected, tested and maintained in accordance with ULC Standard CAN/ULC-S536 and any other

requirements of the local authority having jurisdiction.

Testing should be done as a minimum as described below

1. Notify the fire department or other receiving station if alarm, supervisory and/or trouble signals are transmitted.

2. Notify the proper building personnel so that audible and/or visual signals can be ignored.

3. If the release panel is monitored by a building fire alarm panel, take appropriate action to eliminate any unwanted events.

4. Momentarily open each of the following circuits.

Each initiating device zone

Supervisory circuit

Notification Appliance/Releasing circuit - observe that this results in a trouble condition and all indicators operate as

described in the appropriate preceding section for the particular circuit that is faulted.

RED OUTPUT LED STEADY: ABORT

ZONE 1

ZONE 2

ZONE 3

ZONE 4

OUTPUT 1

Fire Alarm Annunciator Model 5235 User Manual Free

OUTPUT 2

Check out our support resources for your Galaxy S7 SM-G930T to find manuals, specs, features, and FAQs. You can also register your product to gain access to Samsung's world-class customer support. Galaxy s7 sm-g930t user manual.

OUTPUT 3

OUTPUT 4

AC POWER

POWER TBL

SYSTEM TBL

SUP TBL

GROUND FAULT

SUP 1/ABORT

SUPERVISORY 2

COMMON ALARM

ALARM SILENCE

STEADY: DISCHARGING

FLASHING: PRE-DISCHARGE

Fire Alarm Annunciator Model 5235 User Manual Pdf

LAMP TEST

SILENCE

DWG# 3550-17