Agilent 1290 Quaternary Pump User Manual
This versatile and highly reliable pump offers flow rates up to 10 mL/min and pressures up to 600 bar. It is suited for the use of smaller particle size columns giving higher resolution and faster separations. It maintains virtually pulse-free, well mixed and stable solvent flows. Its dual floating, precise servo-controlled pistons adjust the stroke volume according to your chosen flow rate. Offering access to up to four solvents, the 1260 Infinity II Quaternary Pump provides the greatest flexibility in automated solvent blending. It is recommended for a wide range of research and routine applications (especially in the food, environmental and pharmaceutical sectors) as well as for method development.
104 1290 Infinity II High Speed Pump User Manual 7 Maintenance Introduction to Maintenance Introduction to Maintenance Figure 9 on page 104 shows the main user accessible assemblies of the Agilent 1290 Infinity II High Speed Pump. These parts can be accessed from the front (simple repairs) and don’t require to remove the pump from the system. Agilent Technologies 1290 User Manual. Download Operation & user’s manual of Agilent Technologies G4204A Laboratory Equipment, Water Pump for Free or View it Online on All-Guides.com. Agilent technologies 1290 infinity Pdf User Manuals. View online or download Agilent technologies 1290 infinity User Manual. 7 Control Module Screens for the Quaternary Pump This chapter is intended to introduce an operator to the screens available for operation of the Agilent 1100 quaternary pump with the Agilent 1100 control module. Please use the manual of the control module for further detailed reference.
Agilent 1290 Binary Pump User Manual
/FeaturesSectionPageletTemplate -->104 1290 Infinity II High Speed Pump User Manual 7 Maintenance Introduction to Maintenance Introduction to Maintenance Figure 9 on page 104 shows the main user accessible assemblies of the Agilent 1290 Infinity II High Speed Pump. These parts can be accessed from the front (simple repairs) and don’t require to remove the pump from the system. Oct 27, 2015 Agilent 1290 Infinity Quaternary Pump Kromat Kft. Unsubscribe from Kromat Kft.? Agilent 1290 infinity II UHPLC - Duration: 3:44. Campilab Ltd. 29,093 views. Centurylink actiontec c1900a user's manual instructions.
Agilent 1290 Quaternary Pump Manual
- Higher resolution, faster separations - the maximum pressure of 600 bar allows you to use smaller particle size columns, longer columns and/or higher viscous solvents as an alternative to acetonitrile.
- Analytical and semi-preparative purifications - the wide flow range (up to 10 mL/min) perfectly supports standard and semi-preparative applications. The perfect choice for 4.6 and 3.0 mm id columns.
- Quicker experiments - the pump offers convenient access to up to four solvents for isocratic or gradient analysis, which can really speed up method development, preparation of mobile phases and system flushing.
- Easy, fast and secure transfer of methods - from conventional to sub-2-micron columns.
- Integrated degasser
- Longevity and low operating costs - robust materials (stainless steel, titanium, gold, ruby, sapphire, ceramics, PEEK and PTFE) withstand the most demanding applications and keep your pump functioning for years. Our optional seal wash for high-salt mobile phases keeps maintenance to a minimum and reduces operating costs.